new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Jul 16

VIGOR: Visual Goal-In-Context Inference for Unified Humanoid Fall Safety

Reliable fall recovery is critical for humanoids operating in cluttered environments. Unlike quadrupeds or wheeled robots, humanoids experience high-energy impacts, complex whole-body contact, and large viewpoint changes during a fall, making recovery essential for continued operation. Existing methods fragment fall safety into separate problems such as fall avoidance, impact mitigation, and stand-up recovery, or rely on end-to-end policies trained without vision through reinforcement learning or imitation learning, often on flat terrain. At a deeper level, fall safety is treated as monolithic data complexity, coupling pose, dynamics, and terrain and requiring exhaustive coverage, limiting scalability and generalization. We present a unified fall safety approach that spans all phases of fall recovery. It builds on two insights: 1) Natural human fall and recovery poses are highly constrained and transferable from flat to complex terrain through alignment, and 2) Fast whole-body reactions require integrated perceptual-motor representations. We train a privileged teacher using sparse human demonstrations on flat terrain and simulated complex terrains, and distill it into a deployable student that relies only on egocentric depth and proprioception. The student learns how to react by matching the teacher's goal-in-context latent representation, which combines the next target pose with the local terrain, rather than separately encoding what it must perceive and how it must act. Results in simulation and on a real Unitree G1 humanoid demonstrate robust, zero-shot fall safety across diverse non-flat environments without real-world fine-tuning. The project page is available at https://vigor2026.github.io/

  • 4 authors
·
Feb 18

Tensegrity crutches with compliance from a pre-stressed self-tensile module improve ground reaction force profiles, speed, effort, comfort, and perceived stability

Purpose: Six million people use crutches as mobile aids in the US. Rigid designs with no axial mobility limit sensory feedback and lead to secondary injury on the upper joints. Spring-loaded designs offer compliance but may compromise stability. We designed a biologically inspired tensegrity crutch with a compliant module aiming to achieve favorable mechanical properties. The terminal module was a pre-stressed self-tensile two-cell tensegrity structure. We compared the tensegrity crutch to commercial rigid and spring-loaded crutches in mechanical tests using axial loading, in overground straight and turning walking, and in participant experience. Methods: In human trials, healthy young adults (N=18) with no recent lower-body injury performed straight walking and turning trials at a comfortable self-selected pace. A knee blocker simulated unilateral injury of the dominant leg. After using each type of crutch, participants reported their perceived levels of effort, comfort, pain, stability, and usability. Results: Compared to the rigid design, both spring-loaded and tensegrity conditions reduced peak loading rates. The tensegrity design improved effort, comfort, pain, and usability. Spring-loaded crutches reduced perceived stability and walking speed. Conclusion: The biologically inspired tensegrity crutches were an overall improvement to existing designs. Simulations and mechanical testing suggest that nonlinear stiffness, ground-following, and force feedback are among the beneficial mechanical properties that underlie this improvement.

  • 6 authors
·
May 3

Learning Getting-Up Policies for Real-World Humanoid Robots

Automatic fall recovery is a crucial prerequisite before humanoid robots can be reliably deployed. Hand-designing controllers for getting up is difficult because of the varied configurations a humanoid can end up in after a fall and the challenging terrains humanoid robots are expected to operate on. This paper develops a learning framework to produce controllers that enable humanoid robots to get up from varying configurations on varying terrains. Unlike previous successful applications of humanoid locomotion learning, the getting-up task involves complex contact patterns, which necessitates accurately modeling the collision geometry and sparser rewards. We address these challenges through a two-phase approach that follows a curriculum. The first stage focuses on discovering a good getting-up trajectory under minimal constraints on smoothness or speed / torque limits. The second stage then refines the discovered motions into deployable (i.e. smooth and slow) motions that are robust to variations in initial configuration and terrains. We find these innovations enable a real-world G1 humanoid robot to get up from two main situations that we considered: a) lying face up and b) lying face down, both tested on flat, deformable, slippery surfaces and slopes (e.g., sloppy grass and snowfield). To the best of our knowledge, this is the first successful demonstration of learned getting-up policies for human-sized humanoid robots in the real world. Project page: https://humanoid-getup.github.io/

  • 4 authors
·
Feb 17, 2025 3

VIGMA: An Open-Access Framework for Visual Gait and Motion Analytics

Gait disorders are commonly observed in older adults, who frequently experience various issues related to walking. Additionally, researchers and clinicians extensively investigate mobility related to gait in typically and atypically developing children, athletes, and individuals with orthopedic and neurological disorders. Effective gait analysis enables the understanding of the causal mechanisms of mobility and balance control of patients, the development of tailored treatment plans to improve mobility, the reduction of fall risk, and the tracking of rehabilitation progress. However, analyzing gait data is a complex task due to the multivariate nature of the data, the large volume of information to be interpreted, and the technical skills required. Existing tools for gait analysis are often limited to specific patient groups (e.g., cerebral palsy), only handle a specific subset of tasks in the entire workflow, and are not openly accessible. To address these shortcomings, we conducted a requirements assessment with gait practitioners (e.g., researchers, clinicians) via surveys and identified key components of the workflow, including (1) data processing and (2) data analysis and visualization. Based on the findings, we designed VIGMA, an open-access visual analytics framework integrated with computational notebooks and a Python library, to meet the identified requirements. Notably, the framework supports analytical capabilities for assessing disease progression and for comparing multiple patient groups. We validated the framework through usage scenarios with experts specializing in gait and mobility rehabilitation. VIGMA is available at https://github.com/komar41/VIGMA.

  • 5 authors
·
Apr 24, 2025

Evidence-Grounded AI for Musculoskeletal Care

Musculoskeletal diseases are among the leading causes of disability worldwide and create the greatest global need for rehabilitation. Because recovery, remodelling and degeneration often unfold over months to years, musculoskeletal care requires longitudinal management that repeatedly integrates evolving patient evidence, external medical knowledge and stage-specific functional goals. In routine practice, this evidence is fragmented across visits, departments and hospital systems, limiting individualized, evidence-based care. Here we report OrthoPilot, a clinical artificial intelligence system powered by a large language model that integrates hospital data streams with authoritative external knowledge for continuous musculoskeletal management. OrthoPilot autonomously retrieves real-time imaging, laboratory, pathology and order data and converts evolving patient states into evidence-based decisions from admission diagnosis to rehabilitation planning. We established a specialist-validated benchmark from real-world electronic health records spanning 1,000 disease codes. In a reader study across the complete care pathway, OrthoPilot was compared with 81 orthopaedic physicians and surpassed experts with 25 years of experience in diagnostic reasoning, clinical decision-making and management planning. It also outperformed all evaluated intelligent systems across 60 external clinical centres. In a prospective study of 1,870 complex cases, OrthoPilot increased full-chain management success by 10.6%. During an 8-month randomised deployment involving 8,240 inpatients, it increased cumulative cases per bed by 9.7% and improved patient-reported access to health information. These results move clinical AI from predicting isolated events toward executing longitudinal management across complete musculoskeletal care pathways.

  • 37 authors
·
Jul 13 1

KinTwin: Imitation Learning with Torque and Muscle Driven Biomechanical Models Enables Precise Replication of Able-Bodied and Impaired Movement from Markerless Motion Capture

Broader access to high-quality movement analysis could greatly benefit movement science and rehabilitation, such as allowing more detailed characterization of movement impairments and responses to interventions, or even enabling early detection of new neurological conditions or fall risk. While emerging technologies are making it easier to capture kinematics with biomechanical models, or how joint angles change over time, inferring the underlying physics that give rise to these movements, including ground reaction forces, joint torques, or even muscle activations, is still challenging. Here we explore whether imitation learning applied to a biomechanical model from a large dataset of movements from able-bodied and impaired individuals can learn to compute these inverse dynamics. Although imitation learning in human pose estimation has seen great interest in recent years, our work differences in several ways: we focus on using an accurate biomechanical model instead of models adopted for computer vision, we test it on a dataset that contains participants with impaired movements, we reported detailed tracking metrics relevant for the clinical measurement of movement including joint angles and ground contact events, and finally we apply imitation learning to a muscle-driven neuromusculoskeletal model. We show that our imitation learning policy, KinTwin, can accurately replicate the kinematics of a wide range of movements, including those with assistive devices or therapist assistance, and that it can infer clinically meaningful differences in joint torques and muscle activations. Our work demonstrates the potential for using imitation learning to enable high-quality movement analysis in clinical practice.

  • 1 authors
·
May 18, 2025

High-density Electromyography for Effective Gesture-based Control of Physically Assistive Mobile Manipulators

Injury to the cervical spinal cord can cause quadriplegia, impairing muscle function in all four limbs. People with impaired hand function and mobility encounter significant difficulties in carrying out essential self-care and household tasks. Despite the impairment of their neural drive, their volitional myoelectric activity is often partially preserved. High-density electromyography (HDEMG) can detect this myoelectric activity, which can serve as control inputs to assistive devices. Previous HDEMG-controlled robotic interfaces have primarily been limited to controlling table-mounted robot arms. These have constrained reach capabilities. Instead, the ability to control mobile manipulators, which have no such workspace constraints, could allow individuals with quadriplegia to perform a greater variety of assistive tasks, thus restoring independence and reducing caregiver workload. In this study, we introduce a non-invasive wearable HDEMG interface with real-time myoelectric hand gesture recognition, enabling both coarse and fine control over the intricate mobility and manipulation functionalities of an 8 degree-of-freedom mobile manipulator. Our evaluation, involving 13 participants engaging in challenging self-care and household activities, demonstrates the potential of our wearable HDEMG system to profoundly enhance user independence by enabling non-invasive control of a mobile manipulator.

  • 4 authors
·
Dec 12, 2023

A Hierarchical Framework for Humanoid Locomotion with Supernumerary Limbs

The integration of Supernumerary Limbs (SLs) on humanoid robots poses a significant stability challenge due to the dynamic perturbations they introduce. This thesis addresses this issue by designing a novel hierarchical control architecture to improve humanoid locomotion stability with SLs. The core of this framework is a decoupled strategy that combines learning-based locomotion with model-based balancing. The low-level component consists of a walking gait for a Unitree H1 humanoid through imitation learning and curriculum learning. The high-level component actively utilizes the SLs for dynamic balancing. The effectiveness of the system is evaluated in a physics-based simulation under three conditions: baseline gait for an unladen humanoid (baseline walking), walking with a static SL payload (static payload), and walking with the active dynamic balancing controller (dynamic balancing). Our evaluation shows that the dynamic balancing controller improves stability. Compared to the static payload condition, the balancing strategy yields a gait pattern closer to the baseline and decreases the Dynamic Time Warping (DTW) distance of the CoM trajectory by 47\%. The balancing controller also improves the re-stabilization within gait cycles and achieves a more coordinated anti-phase pattern of Ground Reaction Forces (GRF). The results demonstrate that a decoupled, hierarchical design can effectively mitigate the internal dynamic disturbances arising from the mass and movement of the SLs, enabling stable locomotion for humanoids equipped with functional limbs. Code and videos are available here: https://github.com/heyzbw/HuSLs.

HealthiVert-GAN: A Novel Framework of Pseudo-Healthy Vertebral Image Synthesis for Interpretable Compression Fracture Grading

Osteoporotic vertebral compression fractures (VCFs) are prevalent in the elderly population, typically assessed on computed tomography (CT) scans by evaluating vertebral height loss. This assessment helps determine the fracture's impact on spinal stability and the need for surgical intervention. However, clinical data indicate that many VCFs exhibit irregular compression, complicating accurate diagnosis. While deep learning methods have shown promise in aiding VCFs screening, they often lack interpretability and sufficient sensitivity, limiting their clinical applicability. To address these challenges, we introduce a novel vertebra synthesis-height loss quantification-VCFs grading framework. Our proposed model, HealthiVert-GAN, utilizes a coarse-to-fine synthesis network designed to generate pseudo-healthy vertebral images that simulate the pre-fracture state of fractured vertebrae. This model integrates three auxiliary modules that leverage the morphology and height information of adjacent healthy vertebrae to ensure anatomical consistency. Additionally, we introduce the Relative Height Loss of Vertebrae (RHLV) as a quantification metric, which divides each vertebra into three sections to measure height loss between pre-fracture and post-fracture states, followed by fracture severity classification using a Support Vector Machine (SVM). Our approach achieves state-of-the-art classification performance on both the Verse2019 dataset and our private dataset, and it provides cross-sectional distribution maps of vertebral height loss. This practical tool enhances diagnostic sensitivity in clinical settings and assisting in surgical decision-making. Our code is available: https://github.com/zhibaishouheilab/HealthiVert-GAN.

  • 6 authors
·
Mar 7, 2025

Shape it Up! Restoring LLM Safety during Finetuning

Finetuning large language models (LLMs) enables user-specific customization but introduces critical safety risks: even a few harmful examples can compromise safety alignment. A common mitigation strategy is to update the model more strongly on examples deemed safe, while downweighting or excluding those flagged as unsafe. However, because safety context can shift within a single example, updating the model equally on both harmful and harmless parts of a response is suboptimal-a coarse treatment we term static safety shaping. In contrast, we propose dynamic safety shaping (DSS), a framework that uses fine-grained safety signals to reinforce learning from safe segments of a response while suppressing unsafe content. To enable such fine-grained control during finetuning, we introduce a key insight: guardrail models, traditionally used for filtering, can be repurposed to evaluate partial responses, tracking how safety risk evolves throughout the response, segment by segment. This leads to the Safety Trajectory Assessment of Response (STAR), a token-level signal that enables shaping to operate dynamically over the training sequence. Building on this, we present STAR-DSS, guided by STAR scores, that robustly mitigates finetuning risks and delivers substantial safety improvements across diverse threats, datasets, and model families-all without compromising capability on intended tasks. We encourage future safety research to build on dynamic shaping principles for stronger mitigation against evolving finetuning risks.

  • 5 authors
·
May 22, 2025

HomeSafe-Bench: Evaluating Vision-Language Models on Unsafe Action Detection for Embodied Agents in Household Scenarios

The rapid evolution of embodied agents has accelerated the deployment of household robots in real-world environments. However, unlike structured industrial settings, household spaces introduce unpredictable safety risks, where system limitations such as perception latency and lack of common sense knowledge can lead to dangerous errors. Current safety evaluations, often restricted to static images, text, or general hazards, fail to adequately benchmark dynamic unsafe action detection in these specific contexts. To bridge this gap, we introduce HomeSafe-Bench, a challenging benchmark designed to evaluate Vision-Language Models (VLMs) on unsafe action detection in household scenarios. HomeSafe-Bench is contrusted via a hybrid pipeline combining physical simulation with advanced video generation and features 438 diverse cases across six functional areas with fine-grained multidimensional annotations. Beyond benchmarking, we propose Hierarchical Dual-Brain Guard for Household Safety (HD-Guard), a hierarchical streaming architecture for real-time safety monitoring. HD-Guard coordinates a lightweight FastBrain for continuous high-frequency screening with an asynchronous large-scale SlowBrain for deep multimodal reasoning, effectively balancing inference efficiency with detection accuracy. Evaluations demonstrate that HD-Guard achieves a superior trade-off between latency and performance, while our analysis identifies critical bottlenecks in current VLM-based safety detection.

From Pixels to Newtons: Predicting In Vivo Joint Contact Forces from Monocular Video

Joint contact forces govern implant longevity, cartilage health, and rehabilitation outcomes, shaping who develops osteoarthritis, who recovers well from joint replacement, and who benefits from biomechanical interventions. Yet they remain measurable only invasively, in a few dozen patients with instrumented implants. I present a physics-free pipeline to predict instantaneous 3D hip and knee contact forces from an uncalibrated monocular video: no markers, force plates, electromyography, subject-specific imaging, or musculoskeletal model. Parametric body meshes are recovered per frame, encoded as kinematic features, and decoded into forces by a transformer whose pose stream is adaptively modulated at every layer by body shape, joint, side, activity text, and self-supervised video tokens (V-JEPA 2), unifying hip and knee in a single model. Under leave-one-subject-out cross-validation across 26 patients and 25 activity categories from the in vivo OrthoLoad database, the pipeline matches the accuracy of subject-specific musculoskeletal simulations (0.32 pm 0.08 BW RMSE for hip; 0.23 pm 0.03 BW for knee) and resolves peak force changes smaller than those reported for gait retraining and osteoarthritis progression. Applied zero-shot to an independent instrumented cohort, it rivals or outperforms prior published methods. Even without curated activity labels, video features alone preserve accuracy and enable end-to-end inference on raw footage. Driven by the predictor, a generative motion prior produces biomechanically plausible variants with reduced peak loading, rediscovering strategies from the predictive simulation literature. This pipeline establishes uncalibrated monocular video as a viable modality for estimating joint loading, opening a path toward retrospective analysis of archived clinical recordings, primary-care screening, and at-home rehabilitation tracking.

  • 1 authors
·
Jun 3

Reducing Annotation Burden in Physical Activity Research Using Vision-Language Models

Introduction: Data from wearable devices collected in free-living settings, and labelled with physical activity behaviours compatible with health research, are essential for both validating existing wearable-based measurement approaches and developing novel machine learning approaches. One common way of obtaining these labels relies on laborious annotation of sequences of images captured by cameras worn by participants through the course of a day. Methods: We compare the performance of three vision language models and two discriminative models on two free-living validation studies with 161 and 111 participants, collected in Oxfordshire, United Kingdom and Sichuan, China, respectively, using the Autographer (OMG Life, defunct) wearable camera. Results: We found that the best open-source vision-language model (VLM) and fine-tuned discriminative model (DM) achieved comparable performance when predicting sedentary behaviour from single images on unseen participants in the Oxfordshire study; median F1-scores: VLM = 0.89 (0.84, 0.92), DM = 0.91 (0.86, 0.95). Performance declined for light (VLM = 0.60 (0.56,0.67), DM = 0.70 (0.63, 0.79)), and moderate-to-vigorous intensity physical activity (VLM = 0.66 (0.53, 0.85); DM = 0.72 (0.58, 0.84)). When applied to the external Sichuan study, performance fell across all intensity categories, with median Cohen's kappa-scores falling from 0.54 (0.49, 0.64) to 0.26 (0.15, 0.37) for the VLM, and from 0.67 (0.60, 0.74) to 0.19 (0.10, 0.30) for the DM. Conclusion: Freely available computer vision models could help annotate sedentary behaviour, typically the most prevalent activity of daily living, from wearable camera images within similar populations to seen data, reducing the annotation burden.

  • 5 authors
·
May 5, 2025

Safe & Accurate at Speed with Tendons: A Robot Arm for Exploring Dynamic Motion

Operating robots precisely and at high speeds has been a long-standing goal of robotics research. Balancing these competing demands is key to enabling the seamless collaboration of robots and humans and increasing task performance. However, traditional motor-driven systems often fall short in this balancing act. Due to their rigid and often heavy design exacerbated by positioning the motors into the joints, faster motions of such robots transfer high forces at impact. To enable precise and safe dynamic motions, we introduce a four degree-of-freedom~(DoF) tendon-driven robot arm. Tendons allow placing the actuation at the base to reduce the robot's inertia, which we show significantly reduces peak collision forces compared to conventional robots with motors placed near the joints. Pairing our robot with pneumatic muscles allows generating high forces and highly accelerated motions, while benefiting from impact resilience through passive compliance. Since tendons are subject to additional friction and hence prone to wear and tear, we validate the reliability of our robotic arm on various experiments, including long-term dynamic motions. We also demonstrate its ease of control by quantifying the nonlinearities of the system and the performance on a challenging dynamic table tennis task learned from scratch using reinforcement learning. We open-source the entire hardware design, which can be largely 3D printed, the control software, and a proprioceptive dataset of 25 days of diverse robot motions at webdav.tuebingen.mpg.de/pamy2.

  • 12 authors
·
Jul 5, 2023

Real-time accident detection and physiological signal monitoring to enhance motorbike safety and emergency response

Rapid urbanization and improved living standards have led to a substantial increase in the number of vehicles on the road, consequently resulting in a rise in the frequency of accidents. Among these accidents, motorbike accidents pose a particularly high risk, often resulting in serious injuries or deaths. A significant number of these fatalities occur due to delayed or inadequate medical attention. To this end, we propose a novel automatic detection and notification system specifically designed for motorbike accidents. The proposed system comprises two key components: a detection system and a physiological signal monitoring system. The detection system is integrated into the helmet and consists of a microcontroller, accelerometer, GPS, GSM, and Wi-Fi modules. The physio-monitoring system incorporates a sensor for monitoring pulse rate and SpO_{2} saturation. All collected data are presented on an LCD display and wirelessly transmitted to the detection system through the microcontroller of the physiological signal monitoring system. If the accelerometer readings consistently deviate from the specified threshold decided through extensive experimentation, the system identifies the event as an accident and transmits the victim's information -- including the GPS location, pulse rate, and SpO_{2} saturation rate -- to the designated emergency contacts. Preliminary results demonstrate the efficacy of the proposed system in accurately detecting motorbike accidents and promptly alerting emergency contacts. We firmly believe that the proposed system has the potential to significantly mitigate the risks associated with motorbike accidents and save lives.

  • 7 authors
·
Mar 27, 2024

Learning Human-Humanoid Coordination for Collaborative Object Carrying

Human-humanoid collaboration shows significant promise for applications in healthcare, domestic assistance, and manufacturing. While compliant robot-human collaboration has been extensively developed for robotic arms, enabling compliant human-humanoid collaboration remains largely unexplored due to humanoids' complex whole-body dynamics. In this paper, we propose a proprioception-only reinforcement learning approach, COLA, that combines leader and follower behaviors within a single policy. The model is trained in a closed-loop environment with dynamic object interactions to predict object motion patterns and human intentions implicitly, enabling compliant collaboration to maintain load balance through coordinated trajectory planning. We evaluate our approach through comprehensive simulator and real-world experiments on collaborative carrying tasks, demonstrating the effectiveness, generalization, and robustness of our model across various terrains and objects. Simulation experiments demonstrate that our model reduces human effort by 24.7%. compared to baseline approaches while maintaining object stability. Real-world experiments validate robust collaborative carrying across different object types (boxes, desks, stretchers, etc.) and movement patterns (straight-line, turning, slope climbing). Human user studies with 23 participants confirm an average improvement of 27.4% compared to baseline models. Our method enables compliant human-humanoid collaborative carrying without requiring external sensors or complex interaction models, offering a practical solution for real-world deployment.

  • 8 authors
·
Oct 16, 2025